<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-26 06-02-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 3/5, 43 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.6 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 41 kHz 6775 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,1 dBr 2,14 dBr 3,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia Nro 4 C-Molli: II. Largo Non Troppo (Rigel) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 41 kHz MIN: 13 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/26 6.01.40 Total samples: 6775 Equivalent time: 0:05:38 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: 3,2 dBr MIN: 0,1 dBr AVE: 2,14 dBr % above 12,2 dBr: 0,0 Last value: 2,0 dBr (2026/01/26 6.01.39) 05.48 05.50 05.52 05.54 05.56 05.58 06.00 -1 0 1 2 3 4 Pm [dBr]